JDOIJournal of Dentistry And Oral Implants2473-1005Open Access PubUnited StatesJDOI-20-365910.14302/issn.2473-1005.jdoi-20-3659research-articleDigital Planning for Mini-Implant Supported Palatal Expander in Open-Bite TreatmentSzuhanekC1*BabatM2PopaA1Department of Orthodontics, Faculty of Dental Medicine, University of Medicine and Pharmacy ‘Victor Babes’, Timisoara, Romania Faculty of Dental Medicine, University of Medicine and Pharmacy ‘Victor Babes’, Timisoara, RomaniaCorresponding authorSashoStoleski1Institute of Occupational Health of R. Macedonia, WHO CC and Ga2len CC, Macedonia.
Szuhanek C, Department of Orthodontics, Faculty of Dental Medicine, University of Medicine and Pharmacy ‘Victor Babes’, Timisoara, Romania, Email: camelia.szuhanek@yahoo.com
The authors have declared that no competing interests exist.
Open bite malocclusion, due to it’s multifactorial etiology, has always been considered a difficult problem to treat. Often associated with transverse maxillary deficiency, this is a real challenge in the field of orthodontics. The traditional approach, for this type of anomaly, in adult patients, is orthognathic surgery and RME (rapid maxillary expansion). There are several approaches to the treatment of adult patients using digital technology. Mini-implant supported palatal expander limits the side effects of the conventional RME and is less invasive compared to orthognathic surgery. Precise and predictable mini-implant insertion, using a customized surgical guide, provides a safe therapeutic approach. This case report combines Cone-beam computed tomography (CBCT), laser scan superimposition, computer-aided design (CAD) and 3D printing in order to design and print a customized surgical guide for orthodontic mini-implant insertion. A CBCT scan was performed to determine the optimal site for mini-implants’ placement. Using the 3Shape Trios Intraoral Scanner the maxilla and the mandible were laser-scanned. Blue Sky Plan 4 software was used to design the surgical guide, and RayWare software was used for printing it. 4 mini-implants were inserted using a safe and predictable technique. The 3D technology represents the future of orthodontics, reducing the risks, chair-side time while providing the best treatment plan for the patient.
mini-implantopen-bite treatmentIntroduction
Open bite is an anomaly with distinct characteristics that can be easily recognized in 25 to 38 % of the orthodontic patients 1. Several etiological factors are responsible for this type of malocclusion such as: facial growth pattern, sucking habits, tongue-thrusting, mouth breathing, adenoid hypertrophy, syndromes, occlusal and eruptive forces, dental ankylosis, and postural mandibular imbalance. 2 Open bite is often associated with transverse maxillary deficiency, one of the most common malocclusions in orthodontics. 3
Rapid maxillary expansion (RME) is the treatment of choice for the transverse maxillary deficiencies and it is achieved through the remodeling of the midpalatal and inter-maxillary sutures, in children and teenagers. 45
Due to the increased inter-digitation of the maxillary sutures and the rigidity of adjacent structures, the prognosis is not that favorable for adult patients. 6 Root resorptions,damage to periodontal tissues,789 technique failure or limitations,10 reduced stability, 11 edemas and soft tissue lesions 12 have been reported as side effects for adult patients.
In order to minimize the side effects of classical RME and to optimize the potential for skeletal expansion in adult patients Lee et al proposed a mini-screw assisted rapid palatal expansion (MARPE) appliance. 13 Mini-screw insertion site is critical and requires careful consideration of the hard and soft tissue, biomechanics, accessibility and patients’s comfort.
Digital technology plays a major role in contemporary orthodontics, changing the rules of conventional workflow. 1415161718 Every procedure, from diagnosis and treatment outcome pre-visualization to the customization of the appliance design and customization of the therapy, is more predictable. 1920. The use of cone beam computer tomography (CBCT) allows for a more detailed diagnosis and selection for an insertion site with adequate bone quantity and quality. The placement of orthodontic mini-implants with a 3D method based on CBCT imaging has been described in recent years. 2122.
Materials & Methods
This study presents the 3D planning for a surgical guide in order to place a mini-implant supported maxillary expander.
In the case presented below, a male patient aged 25 years, with the chief complaint of posterior, skeletal, bilateral cross-bite and anterior open bite, was referred for orthodontic treatment. A rapid palatal expansion appliance was proposed using a skeletal expander anchored on 4 BENEfit® mini-implants.
A CBCT scan was performed to determine the optimal site for mini-implants’ placement. Using the 3Shape Trios Intraoral Scanner the maxilla and the mandible were laser-scanned (Figure 1). Blue Sky Plan 4 software was used to design the surgical guide, and RayWare software was used for printing it.
Digital models
The digital model (stereolitography (STL) files) was superimposed on the CBCT scan (DICOM file (Digital Imaging and Communication in Medicine) file in order to facilitate the optimal positioning of the 4 mini-implants in the anterior hard palate.
Results
The most suitable antero-posterior mini-implant placement site is determined based on the width and thickness of the palatal vault. 4 self-drilling mini-implants (BENEfit®) were selected: 2 in the anterior palate (rugae area): 2.0 x 9 mm (ST-33-54209) and 2 in the posterior palate (para-midsagittal area): 2.0 x 7 mm (ST-33-54207). (Figure 2)
Mini-implant characteristics
The precise position and angulation of the mini-implants is replicated by 4 cylindrical metallic guides taking into consideration the following parameters: bone thickness, soft tissue thickness and anatomical surrounding structures. The most appropriate site for the placement of mini-implants is: 3 mm lateral to the suture in the first premolar region. (Figure 3,Figure 4)
Positioning of the 4 mini-implants, visualized on the basis of the intraoral scan
Positioning of the mini-implants on CBCT, A. Sagittal section, B. Coronal section, C. Axial section
A 3D positioning guide was designed on top of the virtual model with the final mini-implant position. (Figure 5)
Designing the surgical guide
The customized surgical template was 1.8 mm thick layer offset based on the teeth/mucosa/ bracket contour profiles and ranged from incisors to second premolar. The surgical template was designed to cover the entire occlusal surface. (Figure 6)
Custom made surgical guide with mini-implant analogs final design
Patient’s initials are engraved on the outer surface of the guide, as well as the dimensions of the mini-implants in order to provide more safety and not cause confusion during the transfer from the printing office to the dental office (Figure 6).
After this stage, this file was exported in RayWare software (Figure 7) and printed using a autoclavable resin (Surgical Guide-MoonRay).
Final preview of the surgical guide before printing
Discussion
The digital workflow in orthodontics consists of a triad of digital models, orthodontic software and 3D printers and allows for faster digital case planning, improving communication between professionals and patients without the use of physical documents. In addition, the accessibility and ease of use of this technology enables its wide use in diagnostic and treatment planning. 2324 Three-dimensional image processing allows for virtual planning using CAD (computer-aided design) software as well as CAM (computer-aided manufacturing), such as for the manufacture of surgical guides that were originally used in implantology. 2526. It is recommended to combine the knowledge of basic sciences and the evolution of new technologies in order to establish safer therapeutic approaches. 27
Software-based digital orthodontic planning allows the simulation of the mini-implant placement, determining the ideal characteristics (shape, length, diameter and angulation). It also allows the precise and predictable mini-implant insertion.
Conclusion
The 3D technology represents the future of orthodontics, reducing the risks, chair-side time while providing the best treatment plan for the patient.
Acknowledgment
This research was conducted in the Orthodontic Research Center from Faculty of Dental Medicine, “Victor Babes” University of Medicine and Pharmacy, Timisoara.
EspelandLDowlingP AMobarakK AStenvikAThree-yearstability of open-bitecorrectionby 1-piece maxillaryosteotomy20081346066SubtelnyJ DSakudaM196450337358RibeiroG LVieiraG LRitterDTanakaO MWeissheimerANon-surgicallyassisted rapid maxillaryexpansion in adults: A possible alternative. RevClínOrtod Dent Press20065707AndrewJ HRapid expansion of the maxillary dental arch and nasal cavity by opening the midpalatal suture. Angle Orthod1961317390MeikleM CRemodeling the dento facialskeleton: the biological basis of orthodo nticsanddento facial orthopedics. J Dent Res20078611224SunZHueniSTeeB CKimHMechanical strain at alveolar bone andcircummaxillarysuturesduring acute rapid palatal expansion. Am J Orthod Dentofacial Orthop2011139321928ErverdiNOkarIKucukkelesNArbakSA comparison of twodifferent rapid palatal expansiontechniquesfromthepoint of rootresorption199410614751BaysalAUysalTVeliIOzerTKaradedeIHekimogluSEvaluation of alveolar bone lossfollowing rapid maxillary expansionusing cone-beam computedtomography20134328395HandelmanC SWangLBeGoleE AHaasA JNonsurgical rapid maxillaryexpansion in adults: report on 47 casesusingthe Haas expander. AngleOrthod200070212944BaccettiTFranchiLCameronC GMcNamaraJA JrTreatmenttiming for rapid maxillaryexpansion. AngleOrthod200171534350GurelH GMemiliBErkanMSukuricaYLong-termeffects of rapid maxillary expansion followed byfixed appliances. AngleOrthod201080159BettsN JVanarsdallR LBarberH DHiggins-BarberKFonsecaR JDiagnosis and treatment of transversemaxillarydeficiency19951027596LeeK JParkY CParkJ YHwangW SMiniscrew-assistednon surgical palatal expansion before ortho gnathics urgery for a patientwith severe mandibular prognathism. Am J Orthod Dento facial Orthop201013768309ChristensenL2017Digital workflows in contemporary orthodontics. APOS Trends Orthod.;7:12HurtA J2012Digital technology in the orthodontic laboratory. Am J OrthodDentofacOrthop.;141:24524710.1016/j.ajodo.2011.06.045JodaTZaroneFFerrariMThe complete digital workflow in fixed prosthodontics: a systematic review. BMC Oral Health.17:2017124TarrafN EAliD MPresent and the future of digital orthodontics20182437638510.1053/j.sodo.2018.10.002RVan NoortThe future of dental devices is digital201228131210.1016/j.dental.2011.10.014GrafSCornelisM AHauberGameiroGCattaneoP MComputer-aided design and manufacture of hyrax devices: can we really go digital?2017152687087410.1016/j.ajodo.2017.06.016HarrellW E3D diagnosis and treatment planning in orthodontics2009151354110.1053/j.sodo.2008.09.004MainoB GPaolettoELombardoLSicilianiGA three-dimensional digital insertion guide for palatal micro-implant placement20161222ODe GabrieleDallatanaGRivaRVasudavanSWilmesBThe easy driver for placement of palatal micro-implants and a maxillary expander in a single appointment20175111728737DietrichC AEnderAA validationstudy of reconstructed rapid proto typing models produced by two technologies201787578278710.2319/01091-727.1ChakraborthyPKrishnamurthyKDigital Era of Orthodontics: A Review20162113D’haeseJVeldeT Van DeAccuracy and Complications Using Computer-Designed Stereolithographic Surgical Guides for Oral Rehabilitation by Means of Dental Implants: A Review of the Literature. Clin Implant Dent Relat Res201214332133510.1111/j.1708-8208.2010.00275.xZehnderM SConnertTGuided endodontics: accuracy of a novel method for guided access cavity preparation and root canal location2016491096697210.1111/iejNojimaL IMDCGNojimaMini-implant selection protocol applied to MARPE20182359310110.1590/2177-PopaADeheleanCCalniceanuHWatzCBradSSinescuCOA MarcuCS PopaAvramSNicolovMCA Szuhanek2020A Custom-Made Orthodontic Mini-Implant—Effect of Insertion Angle and Cortical Bone Thickness on Stress Distribution with a Complex In Vitro and In Vivo Biosafety Profile.Materials,13, 4789.ISSN 1996-1944; CODEN: MATEG9SzuhanekCMihaiA MSarbuAPricopM20193D Printed Surgical Guides Used in Orthodontics. MATERIALE PLASTICE563657659OvidiuTiberiu DavidCamelia Szuhanek*,Robert Angelo Tuce, Andra Patricia David, Marius Leretter. Polylactic Acid3D Printed Drill Guide for Dental Implants Using CBCT. REV.CHIM.(Bucharest)♦68♦No. 2 ♦2017. Pag341342